Tranquilt Installation Guide Section 2 (of 8)
Robust Detail E-FC-11 (Icopal-Monarfloor Tranquilt)
Corner Detail
- Roll out the Tranquilt quilt over the sub-floor
- Start in the corner
- Provide at least a 150mm Tranquilt upstand at ALL perimeter walls
- Cut out a 150mm x 140mm section with a suitable utility knife
- Apply the Monarfloor Adhesive supplied, to the wall, corner edge and back of the Tranquilt quilt
- Allow the adhesive to 'tack off' and bond to the wall
- Ensure all edges are bonded to form one continual layer with no splits or voids
- Apply tape over the vertical corner edge