Print

Sequence Seven

 

   Tranquilt Installation Guide Section 7 (of 8)

Robust Detail E-FC-11 (Icopal-Monarfloor Tranquilt)

 

SVP's / Service Pipes Through Floors

  • Service pipe penetrations through precast slabs should be grout filled and sealed in accordance with Robust Detail requirements
  • SVP's should be wrapped with 25mm (min) mineral wool quilt (min 10kg/m3) as required by Robust Details.
  • 100mm timber formwork should be mounted adjacent to pipe (on three sides and not in contact with any pipework)
  • The Tranquilt should be applied with 150mm (min) upstand
  • Any gaps in the Tranquilt should be filled with Tranquilt sections, as done previous
  • All joints between Tranquilt and cut sections should be glued and taped

 

 

 